Water Allocation Based on Source Capacity, Non-Revenue Water (NRW), and Customer Priority at PT Air Minum Giri Menang Perseroda Mataram."
Downloads
The operational reliability condition of the pipeline network in the West Lombok Regional Government Housing Area is currently facing technical challenges in maintaining the continuity of flow to the downstream side of consumers. Based on preliminary studies and analysis of global water balance conducted using official annual volume data from agencies for the period of 2024, the level of network leakage or Non-Revenue Water (NRW) in the residential cluster is calculated to have exceeded 40%. This study aims to determine the effective capacity of the system in meeting the water needs of each zone through a tiered allocation simulation based on the priority order of the AHP-SAW method. The results of the analysis show that the water source capacity (safe yield) is still within safe limits for the potential for aquifer recharge. Real production reached 132,095,000 m³/year or 83.77% of installed capacity, indicating that the pump has been operating close to its optimal capacity. Meanwhile, the ecological exploitation index of 41.89% shows that groundwater utilization is still within safe and sustainable limits. The existing conditions of NRW show that there is a variation in the rate of water loss in each service zone. Zone 1 has an estimated NRW of 48.690%, followed by zone 2 and zone 3. The simulation results show that the effective capacity has not been able to meet all the water needs of each zone at the same time.
Alegre, H., Baptista, J. M., Cabrera, E., Jr., Cubillo, F., Duarte, P., Hirner, W., Merkel, W., & Parena, R. (2016). Performance indicators for water supply services (3rd ed.). IWA Publishing.
Bello, O., et al. (2019). Solving management problems in water distribution networks: A survey of approaches and mathematical models. Water, 11(3), Article 562. https://doi.org/10.3390/w11030562
Bouramdane, A.-A. (2023). Optimal water management strategies: Paving the way for sustainability in smart cities. Smart Cities, 6(5), 2849–2882. https://doi.org/10.3390/smartcities6050128
Coleman, N., Esmalian, A., & Mostafavi, A. (2020). Equitable resilience in infrastructure systems: Empirical assessment of disparities in hardship experiences of vulnerable populations during service disruptions. Natural Hazards Review, 21(4), Article 04020034. https://doi.org/10.1061/(ASCE)NH.1527-6996.0000403
Fitriyani, R. (2020). Model optimasi alokasi air dengan mempertimbangkan prioritas pelanggan di PDAM Kota Surabaya. Jurnal Teknik Sipil dan Lingkungan, 8(1), 15–24.
Frauendorfer, R., & Liemberger, R. (2010). The issues and challenges of reducing non-revenue water. Asian Development Bank.
Furlong, K., & Kooy, M. (2017). Worlding water supply: Thinking beyond the network in Jakarta. International Journal of Urban and Regional Research, 41(6), 888–903. https://doi.org/10.1111/1468-2427.12582
Giudicianni, C., et al. (2020). Zero-net energy management for the monitoring and control of dynamically-partitioned smart water systems. Journal of Cleaner Production, 252, Article 119745. https://doi.org/10.1016/j.jclepro.2019.119745
Gowela, J. J., Alleyne, T., & Chinopfukutwa, G. L. (2017). Service quality gap analysis to improve public water service delivery in Lilongwe City: Tapping customer’s voice. Journal of Environment and Earth Science, 7(4), 117–128.
Hendricks, M. D., & Van Zandt, S. (2021). Unequal protection revisited: Planning for environmental justice, hazard vulnerability, and critical infrastructure in communities of color. Environmental Justice, 14(2), 87–97. https://doi.org/10.1089/env.2020.0038
Hidayati, B. U. R., Hartana, H., & Saadi, Y. (2017). Penentuan prioritas peningkatan pelayanan air bersih PDAM Giri Menang. Spektrum Sipil, 4(1), 95–106.
Ismarmiaty, I., & Rizky, R. (2020). Aplikasi metode simple additive weighting (SAW) untuk penentuan skala prioritas penanganan wilayah krisis air. Jurnal Sistem Informasi dan Komputasi, 14(2), 112–121.
Kodoatie, R. J. (2010). Pengelolaan sumber daya air terpadu. Andi.
Lambert, A., Brown, T. G., Takizawa, M., & Weimer, D. (1999). A review of performance indicators for real losses from water supply systems. Journal of Water Supply: Research and Technology—AQUA, 48(6), 227–237.
Leigh, N. G., & Lee, H. (2019). Sustainable and resilient urban water systems: The role of decentralization and planning. Sustainability, 11(3), Article 918. https://doi.org/10.3390/su11030918
Loucks, D. P., & van Beek, E. (2017). Water resource systems planning and management: An introduction to methods, models, and applications. Springer. https://doi.org/10.1007/978-3-319-44234-1
Poff, N. L., et al. (2016). Sustainable water management under future uncertainty with eco-engineering decision scaling. Nature Climate Change, 6(1), 25–34. https://doi.org/10.1038/nclimate2765
PT Air Minum Giri Menang Perseroda. (2026). Data operasional sistem penyediaan air minum tahun 2025, termasuk data jaringan distribusi, pembagian zona pelayanan, dan atribut spasial [Data internal yang tidak dipublikasikan].
Rahman, D., Saadi, Y., & Yasa, I. W. (2024). Factor causing water loss in the distribution system at PT Air Minum Giri Menang (Perseroda). Research Review International Journal of Multidisciplinary, 9(7), 12–22. https://doi.org/10.31305/rrijm.2024.v09.n07003
Saaty, T. L. (1980). The analytic hierarchy process. McGraw-Hill.
Tangaja, A., Arceo, A., Centino, A., & Camello, M. (2021). Level of user satisfaction and service quality of Mantalongon Water System Cooperative for improved services. International Journal of Sciences: Basic and Applied Research, 60(3), 81–92.
Tchobanoglous, G., Burton, F. L., & Stensel, H. D. (2014). Wastewater engineering: Treatment and resource recovery. McGraw-Hill.
Copyright (c) 2026 Nurul Hidayati, I Wayan Yasa , Hartana Hartana

This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.